To deploy RSD sensors to a single system in each subnet:
- Create a list containing a single system name per subnet:
- Click Menu, Reporting, Queries & Reports, Actions, New.
- On the Result Type page, select System Management, Managed Systems and click Next.
- On the Chart page, select Multi-group Summary Table.
- For the first selection box under Labels are, select Subnet Address.
- For the second selection box under Labels are, select System Name.
- On the line for System Name, click the checkbox and specify that the Maximum items be 1. Click Next.
- On the Columns page, select to have only the System Name column included, and click Next.
- On the Filter page, set Last Communication to Is within the last 1 Day.
- Click Run and then save the query with a new name. In the query output, note that only a single system is listed per subnet.
- Run the query again and select Options, Export Data.
- Select Chart data only for What to export.
- Select the CSV file format option.
- Click Export and save the output file to the local system.
- Open the output file in Excel or a text editor and remove all columns except the System Name column.
- Remove the System Name column label. The resulting file contains a list of system names, for example:
host1
host2
- Apply a tag to the systems in the list from step 1:
- Create a new tag using the ePO Tag Catalog. No criteria are needed for the tag, because it's used later as part of a server task.
- Click Menu, Automation, Server Tasks, New Task Button.
- Name the task and click Next.
- Select Load Systems by File for Actions.
- Copy the output file from step 1o to a local folder on the ePO server.
- Specify the folder and file path in the File Location of the server task.
- Click Apply Tag for Sub-Actions and select the tag created in step 2a.
- Run the server task. This action applies the tag to the systems contained in the file. The server task might be set to 'disabled,' because it needs to run only this one time.
- Install RSD on the systems tagged in step 2:
- Click Menu, System Tree and click the root node My Organization.
- Click Actions, New Client Task Assignment.
- Select Rogue System Detection for Product.
- Click Install RSD for Task Name.
- For Tags, select Send this task to only computers which have the following criteria and select the tag created in step 2a. Click Next.
- Schedule the client task, and click Save.
- Wait for the client task to complete. Then, verify on a few systems that the RSD sensor is displayed as installed on the System Details page.