System processes fail to start during upgrade of Application and Change Control from 8.1.x to 8.2.0
Last Modified: 2024-01-17 11:17:31 Etc/GMT
Affected Products
Languages:
This article is available in the following languages:
Trellix CEO, Bryan Palma, explains the critical need for security that’s always learning.
As per Gartner, "XDR is an emerging technology that can offer improved threat prevention, detection and response."
Trellix announced the establishment of the Trellix Advanced Research Center to advance global threat intelligence.
Trellix Advanced Research Center analyzes threat data on ransomware, nation-states, sectors, vectors, LotL, MITRE ATT&CK techniques, and emails.
After December 1, 2024, please log in to the Thrive Portal for support, knowledge articles, tools, and downloads. For information about using the Thrive Portal, view the Trellix Thrive Portal User Guide.
System processes fail to start during upgrade of Application and Change Control from 8.1.x to 8.2.0
Technical Articles ID:
KB90785
Last Modified: 2024-01-17 11:17:31 Etc/GMT Environment
Application and Change Control (ACC) 8.2.0, 8.1.x Microsoft Windows (all x86 versions) Problem
System processes fail to start when you upgrade from ACC 8.1.x to ACC 8.2.0. NOTE: This issue occurs on all Microsoft Windows x86 versions. Cause
The cause of this issue is that Memory Protection - Critical Address Space Protection (MP-CASP) is enabled during the upgrade process.
Solution
This issue has been corrected in ACC 8.2.1.143 (update 3). ACC 8.1.x clients must be upgraded to ACC 8.2.1.143.
Workaround
Disable MP-CASP before you upgrade to the latest version of ACC. Managed systems:
Affected ProductsLanguages:This article is available in the following languages: |
|