1 PA 6.5.7 update release is only for clients and there is no ePO extension.
Issue resolutions in updates and major releases are cumulative; Technical Support recommends that you install the latest version. To find the most recent release for your product, go to the Product Downloads site.
Critical
Reference Number
Related Article
Found in Version
Resolved in Version
Issue Description
IPA-1576
-
6.5.0
6.5.1
Issue: Security issues are seen in PA agent libraries. For more details, see SB10365.
Non-Critical
Reference Number
Related Article
Found in Version
Resolved in Version
Issue Description
IPA-1900
-
6.5.8
-
Issue: When creating a new benchmark from the checks page, viewing the checks and clicking on the back button results in an unauthorized error.
Workaround: Revisit the Benchmark page and add the required checks.
EPO-11306
-
6.5.5
ePO 5.10 SP 2
Issue: Installing or upgrading the PA extension takes more time on ePO 5.10 SP1 or later.
Workaround: Perform the following steps prior to installing/upgrading the PA extension:
Open C:\Program Files (x86)\Trellix\ePolicy Orchestrator\Server\webapps\deployer\WEB-INF\web.xml.
Change param pluginStartupShutdownDelayMillis from 30000 to 0.
Restart the application service.
Install or upgrade the PA extension.
IPA-1801
-
6.5.5
-
Issue: Running Server task "PA: Benchmark and check synchronization" fails to maintain custom benchmarks after upgrading to 6.5.5.
Workaround: Delete the audit for custom benchmark and create a new one.
IPA-1799
-
6.5.5
-
Issue:AuditManager logger in MacOS crashes while attempting to stop the service.
Workaround: None.
The AuditManager service auto-restarts immediately and there's no impact on product functionality.
IPA-1784
-
6.5.5
-
Issue: Existing NIST Benchmark Audit doesn't return results after extension is upgraded from 6.5.4 to 6.5.5.
Workaround: Delete the audit for NIST benchmark and create a new one.
IPA-1783
-
6.5.5
-
Issue: Running Server task "BME: Benchmark Editor Data Maintenance" doesn't remove obsolete benchmarks.
Workaround: Delete the audit for that reference archived benchmark and create a new one.
IPA-1753
-
6.5.4
6.5.5
Issue: Importing a legacy SCAP 1.1 benchmark throws an error.
IPA-1736
-
6.5.3
-
Issue: Exporting oval results from the Audits page returns an empty ZIP file.
IPA-1703
-
6.5.3
6.5.4
Issue: An incremental scan for other categories like registered extension, system information, and operating system doesn't generate a result.
Workaround: Run a baseline scan for these inventory categories. Generally, these inventory categories aren't set for daily collection as they don't change often.
IPA-1698
-
6.5.3
6.5.4
Issue: The install date is stored as NULL for some applications that use the YYYY-MM-DD format.
IPA-1697
-
6.5.3
-
Issue: When processing inventory scan results from previous PA agent versions, the application type displays the uninstall string.
Workaround: Upgrade to the latest PA 6.5.x agent version.
TSMG-3807
-
6.5.0
6.5.1
Issue: The result of the PA Scan Summary custom query, with the System property filter applied, doesn't appear correctly.
TSMG-4799
-
6.5.0
6.5.1
Issue: The scan incorrectly reports the file version attribute for file objects in Windows 10, Windows 2016, and later.
TSMG-4603
-
6.5.0
6.5.1
Issue: An error occurs while exporting XCCDF results. This issue occurs owing to multiple systems being assigned the same agent GUID.
TSMG-4390
-
6.5.0
6.5.1
Issue: The PA 6.5 agent gets uninstalled owing to the legacy PA agent deploy task.
TSMG-5847
-
6.5.0
6.5.1
Issue: Content updates fail intermittently on the endpoints.
IPA-1511
-
6.5.0
6.5.1
Issue: In the PA Windows agent, the PA folders aren't cleaned up after uninstallation.
IPA-1523
-
6.5.0
6.5.1
Issue: Rules aren't visible for the custom benchmark.
TSMG-5942
-
6.5.0
6.5.1
Issue: EngineMain.exe uses most of the memory on RHEL systems while scanning a shared drive.
MA-8015
-
-
MA 5.6.5
Issue: AuditManager Service terminates intermittently.
Cause: An issue with McAfee Agent (MA).
Resolution: Apply MA 5.6.5, build 401 package 1.
ENSW-104764
-
-
ENS 10.7.0 Update-5, ENS 10.6.1 Update-5
Issue: When running inventory scans, Phoenix engine might hang on endpoints that use ENS-ATP.
Critical
There are currently no critical known issues.
Non-Critical
Reference Number
Related Article
Found in Version
Resolved in Version
Issue Description
TSMG- 3138
-
6.4.3
6.5.1
Issue: The AuditManager service terminates unexpectedly or crashes.
TSMG-797
-
6.4.3
6.5.0
Issue: In the PA server, the purge audit result task deletes the current audit results.
TSMG-1661
-
6.4.3
6.5.0
Issue: In ePolicy Orchestrator (ePO), the console freezes when running the process scan result server task.
TSMG-2185
-
6.4.3
6.5.0
Issue: In the PA Linux agent, an invalid group owner is set to the installed files and directories.
TSMG-2182
-
6.4.3
6.5.0
Issue: In the PA Windows agent, the installation fails owing to restriction to the shared memory path.
1269881
-
-
6.5.0
Issue: In the PA Windows agent, the WMI results with the time_difference function in the OVAL content aren't handled properly.
IPA-990
-
6.4.3
6.5.0
Issue: In ePO 5.10, the tailored benchmark rules aren't editable.
1271690
-
-
6.5.0
Issue: A DB connection leak occurs in the PA 6.4.3 server extension.
-
-
-
Issue: (PA Server Extension) After a PA 6.4 server extension upgrade, the existing scan data can lead to inaccurate results.
Workaround: Technical Support recommends that you perform the following:
Upgrade to PA 6.4.
Run the purge scan data with Delete all scan data.
1267901
-
6.4.3
MA 5.6.1
Issue: With Endpoint Security or VirusScan Enterprise installed, the MA updater fails to update PA content from the endpoint.
Solution: Update PA content on all endpoints by creating an update task in ePO.
1259424
-
6.4.2
-
Issue: The Network interface ID isn't mapped to the corresponding IPs in the ARF report (Mac endpoints only).
1259394
-
6.4.2
PA 6.4.3
Issue: The installed time collected for an application is inaccurate.
1258489
-
6.4.2
-
Issue: Safari browser extension isn't collected on Mac 10.14.
1256516
-
6.4.2
-
Issue: Services collected show the same values for Service Name, Display Name, and Description columns (Mac endpoints only).
1243743
-
6.4.0
6.4.1
Issue: (PA Server Extension) The purge task takes longer to complete when you delete the scans and then run the purge task when there are more than 1,000 systems assigned to the scan.
Workaround: The issue occurs owing to the expansion of the transaction logs. Technical Support recommends that you don't delete the inventory scans. If you want to delete all inventory scan results, use Delete all scan data while you run the purge scan.
NOTE: You can't delete scan results individually.
1240478
-
6.4.0
PA 6.5
Issue: (PA Server Extension) On ePO systems that are in the US time zone, the PA: Scan summary report displays the incorrect date. This incorrect date affects the system count results and consequently the drill-down data.
1238837
-
6.4.0
-
Issue: (PA Agent) The Phoenix engine crashes or doesn't respond when application and registered extensions are collected in a single scan.
Workaround: Technical Support recommends that you create two scans—one to collect application data and the other with all other collections.
1234848
-
6.4.0
-
Issue: (PA Server Extension) Internet Explorer doesn't respond when you export host inventory data in .csv format from the dashboard.
Workaround: Technical Support recommends that you use Google Chrome until the issue is resolved.
1231723
-
6.4.0
PA 6.5
Issue: (PA Server Extension) The scan report for Removed Applications includes Installed Applications.
Critical
There are currently no critical known issues.
Issue: When you remove and reinstall McAfee Agent (MA) on a system, but don't remove the PA agent first, new scan results aren't collected.
Solution: Perform one of the following to gather correct scan results and keep the state intact:
Uninstall the PA agent and MA. (When the system is added again, the new PA agent installation performs a Complete Scan.)
When the client is removed and added back to the System Tree, take note of the new system and perform a full scan on the system by having the Reset Baseline flag set to true.